|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nickel (UHF) & Gold (SMA) Plated Brass Body, Nickel (UHF) & Gold
(SMA) Plated Brass Center Pin, Delrin (UHF) & PTFE (SMA)
Dielectric, “D/TN/GN/G”
|
RG 8/U - 50-57 OHM Coax - 13 AWG 7/21 Bare Copper; Gas Injected Foamed PE; Bare Copper Braid 97% Cov; Black PVC Jacket; .405" NOM OD; 82% Velocity
|
150FT - RG-8U type, 13 AWG stranded (7x21) .085" bare copper conductor, polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket.
|
450 ohm, #18 solid copper clad steel ladder line, PE jacket "Sold By The Foot" Just enter the total number of feet needed in the Qty Box
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RF-9913, 50 ohms, PVC-I 0.405" Jacket, Air Dielectric spiral wrapped PE, #9.5 Conductor, 88% braid plus 100% foil Shield, 84% Velocity of Propagation, and a Capacitance of 24.0 pf/ft.
|
200FT - Series 6, 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II + aluminum braid shield (60% coverage), PVC jacket.
|
Inner Conductor-Solid BC, Dielectric Foam- PE, Outer Conductor-Aluminum Tape, Overall Braid-Tinned Copper, Jacket- PE Black
|
Break Strength 2600 Lbs. Double braided, polyester (AKA Dacron). UV, mildew, rot and stretch resistant low coefficient of friction & high resistance to abrasion.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Davis RF - RG8X LL (low loss) 50 ohm, 16 AWG stranded BC, foam PE, foil shield, w/ TC braid black PVC (type IIA) jacket.
|
RG-11 75 ohm, #14 solid conductor, 97% shield
|
END OF RUN Break Strength 2600 Lbs. Double braided, polyester (AKA Dacron). UV, mildew, rot and stretch resistant low coefficient of friction & high resistance to abrasion.
|
250 FT. 26 AWG, Black PE - Polyethylene Coat highly UV & abrasion resistant. Often referred to as "Kite Wire". Break Strength 25 lbs. 19 strands of copper clad Steel Wire. Weighs.38 lbs per 1000 FT.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14 AWG, 7 Strands - Bare Hard Drawn Copper Wire
|
Break Strength 2600 Lbs. Double braided, polyester (AKA Dacron). UV, mildew, rot and stretch resistant low coefficient of friction & high resistance to abrasion.
|
RG-8XIIA, 50 ohm, 19 stranded #16 conductor, 95% braid, 78% VP, PVC IIA, non-contaminating Jacket
|
Break Strength 260 Lbs. Double braided, polyester (AKA Dacron). UV, mildew, rot and stretch resistant low coefficient of friction & high resistance to abrasion.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14 AWG, 7 Strands - Bare Hard Drawn Copper Wire
|
2 Conductor Zip Power Cord ideal for AC and DC power applications, 18 AWG 16/30 Bare Copper
|
450 ohm, #18, 19 strand copper clad steel ladder line, PE jacket. <1500W
|
175FT - 13 AWG stranded (7x21) .089" bare copper conductor, polyethylene Insulation, bare copper braid shield (96% coverage), non-contaminating PVC jacket.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
300 ohm, #18, 19 strand copper clad steel ladder line, PE jacket
|
RG-6 CATV-60, 75 ohm, solid BC, foam polyethylene (PE), foil w/ 60% AL braid coverge, black PVC jacket
|
8-wire cable, two #18 and six #22 stranded copper wires, UV resistant, PE jacket
|
RG8U - 52 ohm, , "Sold By The Foot" Just enter the total number of feet needed in the Qty Box
|
|